Plugs (female)
|
|
 |
For
sea level applications
Voltage rating: 10 KVDC at sea level
Cable: Reynolds type “C” coaxial
cable P/N 167-2669
Braid termination: Crimp
Max. operating current: (RMS) 20 amps
Insulation resistance: 106 megohms
Mating connector: Reynolds receptacle P/N 167-3555.
|
Receptacles (male)
|
|
 |
Voltage rating:10 KVDC rated at
sea level
Pressure: Sealed for 15 psi differential pressure.
Max.
Leakage: 1 X 10-6 cc/sec. He.
Mounting: Front mount. See optional “D” hole
mounting
Mating connector: Mates all Reynolds series 531 plug
cable assemblies. |
|
Cable Assemblies
|
|
|
Double ended 10 KVDC cable assembly for
sea level operation
Uses Reynolds type “C” coaxial cable P/N 167-2669
Mates series 531 panel connector P/N 167-3555.
100% tests: 15 KVDC applied at sea level and ambient
temperature in mated condition for 15 seconds. Continuity test. |
|

|
|
|
|
Single ended 10 KVDC cable assembly for sea level
operation
Pigtail end termination
Uses Reynolds type “C” coaxial cable P/N 167-2669
Mates series 531 panel connector P/N 167-3555.
100% tests: 15 KVDC at sea level and ambient temperature
in mated condition for 15 seconds. Continuity test. |
|

|
Download this page as a PDF for best print quality.
|
|
|